LASER SYSTEMS

SCHWIND AMARIS® 750S

High-level performance

High Quality by Schwind

The powerful performance laser

The SCHWIND AMARIS 750S offers high performance, proven outcomes and safety. The laser system ablates the cornea at two difference fluence values, thereby achieving a good combination of speed and precision. A very fine laser spot, with a diameter of just 0.54 millimeters (FWHM) ensures smooth corneal modelling. 

With a repetition rate of 750 Hz, the SCHWIND AMARIS 750S achieves very short treatment times. The 6D eye tracker takes 1050 measurements per second to monitor the exact position of the eye in six dimensions. It actively compensates for any deviation with an ablation time of up to 1.5 seconds per dioptre.1 

1  High-­speed recording of thermal load during laser trans-­epithelial corneal refractive surgery using a 750 Hz ablation system. J Optom. De Ortueta D, Arba-­Mosquera S, Magnago T. 2019 Apr – Jun.

Precise: 6D eye tracking


Treatment success is enhanced by SCHWIND’s proprietary active 6D eye tracker which enables a unique level of precision. It is linked to the SCHWIND diagnostic systems and captures all eye motion (static as well as dynamic) during the procedure, for outstanding outcomes.

 

  • Eye-model with visualizing of the six dimensions

During the procedure, it precisely determines and compensates for the following eye movement dimensions:

  1. X-axis
  2. Y-axis
  3. Horizontal rolling
  4. Vertical rolling
  5. Eye rotation around the visual axis: static and dynamic cyclotorsion
  6. Z-axis: active compensation for upward and downward movements

Changes in pupil size are detected, and the laser is adjusted as necessary. In conjunction with the 6D eye tracker, this automatic function ensures correct centring throughout the procedure.

Patient expectations are constantly increasing with regard to treatment methods and the results attainable in corneal  surgery. If you can offer the shortest treatment times with perfect results, you have the upper hand. This is where the SCHWIND AMARIS family of laser systems sets a new standard, delivering greater safety and patient comfort.

Innovative and reliable

The SCHWIND AMARIS 1050RS is a major milestone in refractive corneal surgery, achieving a repetition rate of 1050 Hz, currently is one of the highest of any excimer laser in the market. This innovative excimer laser decreases the extremely short ablation time of the product family even further, to 1.3 seconds per dioptre2 – the ablation times achieved with the AMARIS 750S and AMARIS 500E are no less impressive. In practical terms this means shorter treatment times and minimised risk of corneal dehydration. Moreover, the length of time the patient has to fixate on the green light is significantly shorter.

  1. LASIK myopia without astigmatism, 12.5 mm vertex distance, 6 mm optical zone
  • Comparison of ablation time with products of the AMARIS-family

    SCHWIND AMARIS product family: ablation time per dioptre (s / D)2

The clinical results with the SCHWIND AMARIS laser 
are the best I have ever seen.

Michiel Luger, MD, Bergman Clinics, Utrecht, Netherlands

High performance laser for refractive and therapeutic corneal surgery

Active 6D eye tracking

SCHWIND CAM offers broad range of applications

Gentle & incision-free treatment with SmartSurfACE 

Convenience for doctor and patient through swivel laser arm

User friendly design

*LASIK, without astigmatism, 12.5 HSA, 6 mm optical zone

6D Eyetracking with SCHWIND Amaris 750S Eye laser - Audio Version
Please accept marketing-cookies to watch this video (YouTube).
  • Close-up of the product from above

Plan individually for each situation

Comprehensive treatment planning with complete diagnostic data

  • Overview of treatment structure with SCHWIND software

Each treatment is different. That is why the entire AMARIS product family, with the modular SCHWIND CAM software, makes it possible for you to plan treatment individually for your patients across an exceptionally wide range of applications in corneal surgery. Whether corneal or ocular wavefront, pachymetry or epithelial data – all the required diagnostic information are incorporated into planning.

You can be sure that you will not leave out any detail important for  the individual ablation.

SCHWIND CAM modules and the advantages for you


ORK-CAM

A one-of-a-kind intelligent planning tool for wide-ranging and tailor-made refractive laser treatment. Aspheric ablation profiles are employed for both aberration-free and customised treatments based on (total) corneal or ocular wavefront data.

PresbyMAX

This module is ideal for safe and efficient treatment of patients with emmetropia, myopia, hyperopia and astigmatism, whose accommodative response is limited. PresbyMAX is based on bi-aspheric ablation profiles.

PTK-CAM  

This module supports you in performing therapeutic treatments. Superficial as well as deep corneal scars and corneal degenerations can be exactly localized and treated with a procedure in which the corneal tissue is ablated in either a circular, elliptical or an individualised shape. You can choose between a more superficial refraction-neutral or a deep ablation for performing laser keratoplasty.

Touch-free treatment with SmartSurfACE 

SmartSurfACE combines the benefits of touch-free TransPRK surface treatment with innovative SmartPulse Technology.8, 9

It works without touching the eye. There is no suction, no blade and no incision – vision is corrected through the top layers of the cornea with SCHWIND AMARIS technology, gently, touch-free, in a single step. The treatment with SmartSurfACE on regular corneas speeds up the healing process and yields good vision quality even in high myopic eyes.

The advantages over other surface treatment methods are obvious – the epithelium is removed more precisely, more uniformly and more easily than with manual or alcohol-assisted debridement.

SmartSurfACE is suitable for any laser candidate as well as patients with thin corneas, corneal pathologies or complex topographies.

SmartSurfACE Icon
  1. One­Year Visual and Refractive Outcomes of SmartPulse® Technology in Transepithelial Photorefractive Keratectomy for Myopic and Astigmatic Patients. Margarit DA, Stanca HT, Mocanu V, Munteanu M, Ferrari F, Marius S. J Clin Med. 2024 Oct 17;13(20):6182
  2. Trans advanced surface laser ablation (TransPRK) outcomes using SmartPulseTechnology. Aslanides IM, Kymionis GD. Cont Lens Anterior Eye. 2017 Feb;40(1):42­46

Intelligent Thermal Effect Control (ITEC)

Higher safety through corneal temperature monitoring and laser pulse sorting for minimum heating, resulting in very gentle ablation

Automatic Fluence Level Adjustment (AFLA)

Balanced pulse number and energy for the perfect combination of fast treatment and high corneal smoothness

Integrated slit lamp

Immediate postoperative control down to the deep layers of the cornea

Corneal Collagen Crosslinking Lamp

Lamp integrated in the workflow – Ready to use immediately, no additional adjustment necessary

Swivelling laser arm and powered swivelling bed 

Comfort and convenience for patient, doctor and assistants

Treatment Assistant Manager (TAM)

Easier operation through controlled sequence of the operation steps light intensity, microscope magnification and fixation points; each step is individually adjustable

Integrated plume evacuation

Integrated plume evacuation and filter for clean operating theatre air

Automatic video record of treatment

Many teaching, reviewing and marketing possibilities

Product shot of the SCHWIND AMARIS 750S on white background

Automatic Fluence Level Adjustment
Ideal balance between the total number of laser pulses and energy delivered

With the Automatic Fluence Level Adjustment (AFLA), the SCHWIND AMARIS product family achieves desired level of corneal smoothening even at the highest ablation speed.* Researchers at SCHWIND have developed an algorithm that ensures an ideally balanced ratio between the total number of laser pulses and the energy delivered.

About 80 percent of the ablation is performed with a high fluence value. For the fine modelling – the remaining 20 percent – AFLA automatically switches to a lower fluence. The result is optimum smoothing of the cornea. Through the extremely small beam size and Super-Gaussian beam profile, you achieve desired ablation smoothness.


Intelligent Thermal Effect Control (ITEC) is the name  of the thermal control process that prevents damage  to the surrounding corneal tissue, even at the very high ablation speeds of the SCHWIND AMARIS product family. ITEC ensures that the laser pulses are distributed in a  thermally optimised, dynamically adapted way, which gives the individual position on the cornea sufficient  time to cool off. The following pulses can therefore approach an already cooled position faster. ITEC is better than the static processes. Studies using an infrared thermographic camera have proven that the corneal tissue only heats up minimally, even at high ablation speeds.*

  • Heat propagation of a laser pulse with the ITEC method

  • Thermal Sequence in vivo

    Corneal temperature measurements with an infrared thermographic camera

The thermal control technology and ablation control with two fluence levels play a very important role, especially in biological terms: the less the biological interaction with the corneal tissue, the more reliably wounds can heal.

Prof. Jorge Alió, Vissum Medical Ophthalmologic Corporation, Alicante, Spanien

* High-­speed recording of thermal load during laser trans-­epithelial corneal refractive surgery using a 750 Hz ablation system. J Optom. De Ortueta D, Arba-­Mosquera S, Magnago T. 2019 Apr – Jun.

TRUST YOUR EYES

SCHWIND works with selected distribution partners in over 100 countries. You can find your distributor here.

Find representatives  

Ophthalmic surgeons the world over trust our products. Here, some of them discuss their experience with SCHWIND technologies.

User reports